S2000-2 Operating
33 www.bolid.com
Define if necessary the Access Group 2 to Confirm Passage parameter (the number of the ac-
cess group required to be assigned with a second key which must be presented to confirm the
passage in case of the three person access rule
If a two or three access rule is given for an access group of the presented, the IDENTIFICATION
message is generated by the S2000-2 controller, the green LED of the reader starts flashing 5 times
per second, and the controller waits during the next 30 seconds for the presenting the key (the keys)
assigned with the access group (groups) required to confirm the access rights of the presented key.
If the next presented key is assigned with the unmatched access group and does not meet current
access conditions, the controller generates the ACCESS DENIED message with CONFIRMATION
ERROR attribute.
If, otherwise, the next presented key is assigned with the matched access group, but none of the keys
meet access conditions (three person access rule), the IDENTIFICATION message is generated and
during the next 30 seconds the controller waits for the third key to be presented.
If after the second or third key presenting the access conditions are met for at least one of these keys,
access is granted. If the controller operates in Two Entrance Doors or One Entrance/Exit Door mode,
ACCESS GRANTED messages will be generated for all the keys which meet the access conditions.
In all other operating modes, the controller generates the ACCESS GRANTED message for the first
key only.
If not all the persons, involved in the two (three) person ruled access procedure, are supposed to en-
ter the restricted zone (for example: a security officer confirms access of another staff member), it is
necessary to set the Confirmation passage mode for the access group of such the persons. The pas-
sage itself is not permitted for the owners of keys such passage mode and no ACCESS GRANTED
and PASSAGE messages are generated for such the key during the two (three) person rule access
procedure.
Two (three) person rule access control parameters is given for each reader (each passage direction)
individually. For example, to entry a zone (to pass into a zone controlled by one of the readers) the
two person rule is used, while to exit this zone (to pass into a zone controlled by another reader) the
simple access mode (identification of one person only) is sufficient, and vice versa.
Modes of the passing to zones controlled by the first and the second readers of the controller (entry
and exit modes) are given for each access group separately. Thus, for example, all members of one
access group are accessed to a zone based on the two person rule, while the members of another
access group are accessed to the same zone with the simple access mode (via the same reader).
If the two person rule access via one of the controller readers is set for an access group X and an
access group Y is selected to be the Access Group 1 to Confirm Passage parameter value, then: